VERIFY® Dual Species Self-Contained Biological Indicators
Item No. 684218
VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO)
Description
VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes.
VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. Each SCBI is completely self contained within a vial and contains a disc inoculated with dual species bacterial spores (Geobacillus stearothermophilus and Bacillus atrophaeus) and an ampoule of specially formulated soybean casein digest growth medium with a pH indicator. The vial label contains a process indicator for steam and EO.
VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. Each SCBI is completely self contained within a vial and contains a disc inoculated with dual species bacterial spores (Geobacillus stearothermophilus and Bacillus atrophaeus) and an ampoule of specially formulated soybean casein digest growth medium with a pH indicator. The vial label contains a process indicator for steam and EO.
- 24-hour final results for steam sterilization
- 48-hour final results for EO sterilization
- Sturdy design prevents premature activation
- For routine monitoring, qualification and release of loads containing implantable devices.
Specifications
- Pack Size
- 5/pk
- Medicine type
- None
- Use
- None
- NIOSH
- 0
- FedLaw
- None
- Danger Sign 1
- None
- Danger Sign 2
- None
- Danger Sign 3
- None
- Danger Sign 4
- None
- Danger Sign 5
- None
- Display hazardous status
- False
- Hazardous material
- False
Documents
LoadingVERIFY® Dual Species Self-Contained Biological Indicators
Item No. 684218
Description
VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes.
VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. Each SCBI is completely self contained within a vial and contains a disc inoculated with dual species bacterial spores (Geobacillus stearothermophilus and Bacillus atrophaeus) and an ampoule of specially formulated soybean casein digest growth medium with a pH indicator. The vial label contains a process indicator for steam and EO.
VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. Each SCBI is completely self contained within a vial and contains a disc inoculated with dual species bacterial spores (Geobacillus stearothermophilus and Bacillus atrophaeus) and an ampoule of specially formulated soybean casein digest growth medium with a pH indicator. The vial label contains a process indicator for steam and EO.
- 24-hour final results for steam sterilization
- 48-hour final results for EO sterilization
- Sturdy design prevents premature activation
- For routine monitoring, qualification and release of loads containing implantable devices.
Technical data
- Pack Size
- 5/pk
- Medicine type
- None
- Use
- None
- NIOSH
- 0
- FedLaw
- None
- Danger Sign 1
- None
- Danger Sign 2
- None
- Danger Sign 3
- None
- Danger Sign 4
- None
- Danger Sign 5
- None
- Display hazardous status
- False
- Hazardous material
- False

